DMF 8.7.0 provides support for Management Redundancy on an Extensible Operating System (EOS) Fixed System Chassis. It provides a method to enable redundant active/active connectivity on the management IP address for a Danz Monitoring Fabric (DMF) switch in a fixed system chassis using an out-of-band management port and a front-panel port on the switch.

A new configuration command?label local-termination explicit-null?under BGP LU address family allows BGP LU speakers to send explicit-null labels for prefixes for which the router is a terminating LSP node. The prefix is expected to be originating locally (via network command).

The new show command?show configuration consistency?adds the ability to check for ¡°dangling¡± references in the configuration. For example, it is possible to configure an access-list, TEST-ACL, to an interface (ip access-group TEST-ACL in), without actually defining TEST-ACL (ip access-list TEST-ACL). This show command will list such ¡°undefined¡± references.

This feature extends link bandwidth extended community deletion mechanism, which previously always required

The CLI command “show rib route ip[ipv6]” and its sub commands (e.g. “show rib route ip

Unequal cost multi path (UCMP) for BGP is a mechanism for forwarding ECMP route traffic using weights, with which the

This feature implements support for RFC8203/BIS so that users can attach the reason of BGP instance or peer session